Lösungen Westermann: Dämpfung/ Netzwerkumrechnungen/ Schwingkreise/ Kennlinien und Kennwerte

Seite 343 / Dämpfung
1)a) Du = 10; b) Au = 20db

2)U2 = 15,9mV; Du = 25,12

3)
a) Au = 2,45dB; U1 = 0,775V; I1 = 1,29mA; U2 = 0,585V; I2 = 0,974mA
b) Au = 2,45dB; Ai = 2,45dB; Ap = 2,45dB; Du = 1,32; Di = 1,32; Dp = 1,75
c) G = 8,18dB

4) Au = 10,92dB; G = 9,12dB

5) U1 = 0,245mV

6) Au1 = 7,96dB; alpha1 = 9,95dB/100m; Au2 = 20dB; alpha2 = 16dB/100m


Seite 148 Netzwerkumrechnungen
1) Rser = 1,96Ohm; Rpar = 2,66kOhm; Rg = 1,47kOhm


Seite 154/ 153 Schwingkreise
1) fo = 11,7MHz; Q = 30,3; Rpar = Zo = 7,35kOhm

5) a) fo = 360 kHz; Zo = 490 Ohm; b) C = 98pF

11)
63Hz: Z = 90 Ohm; I = 1,33A
55Hz: Z = 50 Ohm; I = 2,4A
67Hz: Z = 90 Ohm; I = 1,33A

15)
41,25 Mhz: L6 = 827nH; L7 = 1,049µH

82,5Mhz: L8 = 138nH; L9 = 158nH

165Mhz: L12 = 37,2nH


Seite 170 Kennlinien und Kennwerte
14) a) fo = 1,3 Mhz; b) UR = 1V: fo1 = 1,15Mhz; UR = 10V: fo10 = 1,22MHz

15) Cges = 631pF; Creihe = 31pF; Cd = 38,3pF; UR = 3V aus Kennlinien-Diagramm für BB104